Xenon Chamber

LIB Industry’s Xenon Chamber (Model XL-S-750) exposes materials to xenon arc light, heat, humidity and water spray at the same time, so you can check how paints, plastics, textiles and car parts hold up outdoors. A rotating holder carries 42 specimens past one 4500 W water-cooled lamp, giving every sample the same dose.

Standards: ISO 4892-2, ASTM G155, SAE J2527
Light Source: 1 × 4500 W water-cooled xenon arc lamp, about 2,000 hours lamp life
Irradiance: 35~150 W/m² (300~400 nm; control at 340 nm or 420 nm)
Temperature: Chamber ambient ~ 100 ℃ ±2 ℃, black panel 35 ~ 85 ℃ ±2 ℃
Humidity: 50% ~ 98% RH (±5% RH)
Capacity: 42 specimens (95×200 mm), rotating holder
Product Description

Xenon Chamber Manufacturer & Supplier: Xenon Arc Weathering Tests for Labs and Factories

LIB Industry is a professional xenon arc test chamber manufacturer in China. Since 2009, it has shipped environmental test equipment to 72+ countries. The chamber combines a water-cooled xenon lamp, a rotating specimen holder, programmable humidity and rain cycles, and a color touch screen in one cabinet. Programs run unattended, and every result is easy to repeat.

Looking for a xenon chamber price? Send LIB Industry your test standard and specimen quantity for a factory-direct quotation.

Why the Test Results Repeat

One Lamp, 42 Specimens: Rotating Holder for Equal Exposure
The holder turns around the 4500 W lamp, so samples at the edge and the center receive the same light.

Xenon Light with Selectable Filters
The water-cooled lamp covers UV, visible and infrared light. Various filters are available for outdoor or behind-glass conditions.

Black Panel Control: 35 ~ 85 ℃ ±2 ℃
Set the surface temperature your standard asks for, apart from the chamber air temperature (ambient ~ 100 ℃ ±2 ℃).

Light, Humidity and Rain in One Cycle
Irradiance 35~150 W/m², humidity 50% ~ 98% RH (±5% RH) and a water spray cycle of 1~9999H59M run in one programmed sequence.

UV Radiometer: ±5% Tolerance
Read irradiance at 340 nm or 420 nm to keep exposure on target.

Clean Water Supply: Automatic Fill and Purification
Automatic water supply with a purification system supports long, unattended runs and protects the lamp cooling circuit.

Technical Specifications of Xenon Chamber

ModelXL-S-750
Internal / Overall Dimensions950×950×850 mm / 1400×1400×1950 mm
Chamber Type / CapacityRotating holder / 42 pcs, holder size 95×200 mm
Light Source1 × 4500 W water-cooled xenon arc lamp
Irradiance / Bandwidth35~150 W/m² / 300~400 nm (340 nm or 420 nm)
Chamber / Black Panel TemperatureAmbient ~ 100 ℃ ±2 ℃ / BPT 35 ~ 85 ℃ ±2 ℃
Humidity50% ~ 98% RH, deviation ±5% RH
Water Spray Cycle1~9999H59M, adjustable
ControllerProgrammable color LCD touch screen
Water System / HumidifierAutomatic water supply with purification / external isolation, stainless steel surface evaporation
RadiometerUV radiometer, tolerance ±5%
Cooling SystemMechanical compression refrigeration; French TECUMSEH compressor; eco-friendly refrigerant
Safety ProtectionOver-temperature, over-current, water shortage, earth leakage, phase sequence
MaterialsInterior SUS304 stainless steel; exterior coated steel plate; polyurethane foam and insulation cotton
Observation WindowInterior lighting, double-layer silicone rubber sealin

Xenon Chamber Details

15.webp

10.webp

20.webp

Water Spray

Water spray pipe is equipped with nozzles

Simulates the outdoor moisture to the material

Irradiation Source

Irradiation Source with 1 piece of 4500 W water-cooled xenon lamp

Various filters available for choose

Cooling system

Mechanical compression refrigeration system

French TECUMSEH compressor

Environmentally friendly refrigerant

4.webp

11.webp

Frequently Asked Questions

1. What is the difference between a xenon test and a UV aging test?
Xenon simulates the full solar spectrum (UV, visible, IR); UV aging focuses mainly on ultraviolet. Choose xenon for fuller sunlight simulation.

2. Can the Xenon Chamber simulate rain?
Yes. The XL-S-750 has a water spray system with adjustable cycles and automatic water supply and purification.

3. How often should the xenon lamp be replaced?
It depends on usage. Check irradiance regularly and replace the lamp when it can no longer maintain test conditions.

4. Does the Xenon Chamber require calibration?
Yes. Irradiance, temperature, and humidity should be checked regularly. Calibration services can be arranged to suit your lab’s requirements.

5. Can the Xenon Chamber be customized?
Yes. Dimensions, specimen holders, and control parameters can be customized. Send your sample size, standards, and test conditions for evaluation.

6. Does LIB Industry provide installation and technical support?
Yes. We provide installation guidance, training, remote assistance, and lifetime technical support. Standard warranty is 36 months.

Request a Quote for Your Xenon Chamber
Send your sample information and applicable standard to LIB Industry for a suitable configuration and quotation.

  • Warranty: 36 months

  • Technical Support: Lifetime