A new coating or plastic formula needs an answer before launch: will it chalk, yellow or crack outdoors? The UV-SI-260 answers it by repeating a day-and-night cycle, UV light by day and condensation like dew by night, with spray for rain, far faster than natural exposure.
For a UV weather test chamber price, send your test standard, panel size and quantity, and LIB Industry will quote the matching configuration.
Equal Exposure for 56 Panels: 50 mm Lamp Distance
Eight lamps and flat holders give every panel the same light, so differences between samples come from the material.
Two Lamp Types: UVA-340 and UVB-313
UVA-340 is the closest match to sunlight for most weathering work. UVB-313 ages faster for quick screening. Lamps are easy to change.
Set Your Own Intensity: 0.3 ~ 20 W/m²
Match the irradiance your standard asks for across the 290 ~ 400 nm UV range.
Day and Night in One Program: UV, Condensation, Spray
Black panel temperature 35 ~ 80 ℃, humidity ≥ 95% RH, and a spray cycle of 1~9999H59M run in a single sequence.
Spray Nozzles for Rain Shock
Ten nozzles (0.5 mm) deliver 0.8 ~ 1.0 ml/80 cm²/h to imitate sudden rain.
Long Unattended Runs: Automatic Water Supply and Purification
Water refills itself, so multi-week tests run without refilling.
| Model | UV-SI-260 |
| Internal / Overall Dimensions | 450×1170×500 mm / 610×1330×1470 mm |
| Specimen Holder / Capacity | 75×150 mm / 56 pcs (flat holders, aluminum panels with rings); special holders can be customized |
| Light Source | 8 × 40 W fluorescent UV lamps (UVA-340 / UVB-313), distance to specimen 50 mm |
| Wavelength / Irradiance | 290 ~ 400 nm / 0.3 ~ 20 W/m² |
| Chamber / Black Panel Temperature | Ambient ~ 90 ℃ ±2 ℃ / 35 ~ 80 ℃ |
| Humidity | ≥ 95% RH |
| Water Spray Cycle | 1~9999H59M, adjustable |
| Controller | Programmable color LCD touch screen, Ethernet connection |
| Water Supply System | Automatic water supply with water purification |
| Safety Protection | Over-temperature, over-current, water shortage, earth leakage, phase sequence |
| Materials | Interior SUS304 stainless steel; exterior steel plate with protective coating |
|
|
|
| Workroom The internal material is 304 stainless steel Flat specimen holders, aluminum panels with rings. | Irradiation Source UVA 340 nm and UVB 313 nm fluorescent UV lamps are available Easy to change UV lamps | Sample Shelf Each specimen size is 75mm * 150mm, can hold 56 pieces. Special sample holder can be customized |
|
|
| Standard | Typical use |
|---|---|
| ASTM G154 | Fluorescent UV exposure of nonmetallic materials |
| ASTM D4587 | Fluorescent UV and condensation exposure of paints and coatings |
| ISO 4892-3 | Plastics: fluorescent UV lamps |
A common cycle alternates UV exposure at a higher temperature with condensation at a lower one, for example 8 hours UV at 60 ℃ then 4 hours condensation at 50 ℃. Send LIB Industry your standard and sample type, and LIB Industry engineers will set up the matching program.
Send LIB Industry your standard, panel size and quantity. LIB Industry engineers will recommend the right setup and send a detailed quotation.